Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Clin Biomech (Bristol, Avon) ; 112: 106178, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38232471

RESUMO

BACKGROUND: Cervical collars restrict cervical spine movement to minimise the risk of spinal cord injury. Collars apply mechanical loading to the skin putting it at risk of skin damage. Indeed, cervical collar-related pressure ulcers are unacceptably prevalent, especially at the occiput, mandibles, and chin. Collar design and fit are often key considerations for prevention. METHODS: This comprehensive study evaluated four commercial prehospital and acute care cervical collars. Pressure, microclimate, transepidermal water loss and skin hydration were measured at the interface between the device and the skin. Range of motion restriction was measured to evaluate effective immobilisation. Head, neck, and shoulder morphology was evaluated using three-dimensional scans. FINDINGS: The occiput experienced significantly higher interface pressures than the chin and mandibles for most collar designs. Interface pressure at the occiput was significantly higher for the Stiffneck extrication collar compared to the other collar designs. The Stiffneck collar also provided the most movement restriction, though not significantly more than other designs. Relative humidity at the device skin interface was significantly higher for the Stiffneck and Philadelphia collars corresponding to closed cell foam padding, in contrast to the open cell foams lined with permeable fabric used in the other collars. Collar discomfort correlated with both occipital pressure and skin humidity. INTERPRETATION: The occiput is at increased risk of cervical collar-related pressure ulcers during supine immobilisation, especially for Stiffneck extrication collars. Lined open-cell foams could be used to minimise skin humidity and increase comfort.


Assuntos
Lesão por Pressão , Humanos , Lesão por Pressão/prevenção & controle , Lesão por Pressão/etiologia , Contenções , Pescoço , Vértebras Cervicais/lesões , Bioengenharia , Imobilização/efeitos adversos
2.
Exp Physiol ; 109(2): 255-270, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37975151

RESUMO

Women continue to be under-represented in thermoregulatory research despite their undergoing unique physiological changes across the lifespan. This study investigated the biophysical, thermo-physiological, and perceptual determinants of cool-seeking behaviour during exercise in younger and older women. Eleven younger (25 ± 5 years; 1.7 ± 0.1 m; 63.1 ± 5.2 kg) and 11 older women (53 ± 6 years; 1.7 ± 0.1 m; 65.4 ± 13.9 kg) performed a 40-min incremental cycling test in a thermoneutral environment (22 ± 1.7°C; 36 ± 4% relative humidity). Throughout the test, participants freely adjusted the temperature of a cooling probe applied to their wrists to offset their thermal discomfort. We continuously recorded the probe-wrist interface temperature to quantify participants' cool-seeking behaviour. We also measured changes in participants' rate of metabolic heat production, core and mean skin temperatures, and skin wetness. Finally, we body-mapped participants' skin heat, cold and wetness sensitivity. Our results indicated that: (1) older and younger women exhibited similar onset and magnitude of cool-seeking behaviour, despite older women presented reduced autonomic heat-dissipation responses (i.e., whole-body sweat losses); (2) older women's thermal behaviour was less determined by changes in core temperature (this being a key driver in younger women), and more by changes in multiple thermo-physiological and biophysical parameters (i.e., physical skin wetness, temperature and heat production); (3) older women did not present lower regional skin thermal and wetness sensitivity than younger women. We conclude that predictions of female cool-seeking behaviours based on thermo-physiological variables should consider the effects of ageing. These findings are relevant for the design of wearable cooling systems and sports garments that meet the thermal needs of women across the lifespan.


Assuntos
Regulação da Temperatura Corporal , Exercício Físico , Humanos , Feminino , Idoso , Regulação da Temperatura Corporal/fisiologia , Exercício Físico/fisiologia , Temperatura Cutânea , Sudorese , Pele , Temperatura Alta
3.
J Wound Ostomy Continence Nurs ; 50(6): 512-520, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37966081

RESUMO

PURPOSE: The purpose of this study was to evaluate temporal changes in skin responses following exposure to moisture alone or moisture in combination with mechanical loading. DESIGN: Comparison cohort with a repeated-measures design. SUBJECTS AND SETTINGS: The sample comprised 12 healthy volunteers. Participants were purposely sampled from 2 different age groups; half were 32 to 39 years old and half were 50 to 62 years old. Participants identified as White, Black, or mixed; 83% (n = 10) identified as White; 8 (67%) were female. METHODS: Four sites at the sacrum were challenged with the application of specimens taken from 2 absorbent products; the pad specimens were applied dry or saturated with synthetic urine (SU; pH = 8); a further site from the sacral skin was also selected and used as a control. Skin assessments were performed at different points in time: (1) 60 minutes after exposure to dry or SU-saturated pad specimens; (2) 60 minutes after exposure to pads and mechanical loading (application of pressure in the form of 45°C high sitting); and (3) 30 minutes after removal of all pads (recovery period). Outcome measures were transepidermal water loss (TEWL), stratum corneum (SC) hydration, erythema, pH, and skin inflammatory biomarkers measured at each of the time points described earlier. RESULTS: The control site and those exposed to dry pads showed minimal time-dependent changes irrespective of the parameter investigated. In contrast, significant increases in TEWL (P = .0000007) and SC hydration responses (P = .0000007) were detected at the sites under absorbent pad specimens after saturation with SU (exposure to moisture). In some participants, TEWL and SC hydration parameters were significantly higher during pressure application. Skin pH remained in the mildly acidic range throughout the test session, and no consistent trends were observed with erythema. Skin inflammatory biomarkers also exhibited considerable variability across participants; none changed significantly over time. Significant differences (P = .02) were also detected following the exposure of moisture in combination with pressure. CONCLUSION: We evaluated an array of parameters to identify changes following skin exposure to 2 absorbent pads in the presence and absence of SU and mechanical loading. Analysis revealed changes in skin barrier properties in the presence of moisture and/or pressure. This observation suggests a need for frequent pad changing as well as periods of skin off-loading to protect the skin health of individuals with incontinence.


Assuntos
Tampões Absorventes para a Incontinência Urinária , Pele , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Estudos de Coortes , Eritema , Biomarcadores
4.
5.
J Dermatol Sci ; 112(2): 63-70, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37953180

RESUMO

BACKGROUND: Pressure ulcers (PUs) are chronic wounds that are detrimental to the quality of life of patients. Despite advances in monitoring skin changes, the structure and function of skin cells over the site of pressure ulcers are not fully understood. OBJECTIVE: The present study aims to evaluate local changes in the properties of superficial corneocytes in category 1 PU sites sampled from a cohort of hospitalised patients. METHODS: Cells were collected from a PU-compromised site and an adjacent control area and their topographical, maturation and mechanical properties were analysed. RESULTS: Corneocytes at the PU-compromised site were characterised by higher levels of immature cornified envelopes (p < 0.001) and greater amounts of desmoglein-1 (corneodesmosomal protein) (p < 0.001) compared to the adjacent control area. The cells at the control site presented the typical ridges-and-valleys topographical features of sacrum corneocytes. By contrast, the PU cells presented circular nano-objects at the cell surface, and, for some patients, the cell topography was deformed. CEs at the PU site were also smaller than at the control site. Although differences were not observed in the mechanical properties of the cells, those of the elderly patients were much softer compared with young subjects. CONCLUSION: This is the first study investigating the changes in corneocyte properties in category I pressure ulcers. Superficial cells at the PU sites showed altered topographical and maturation characteristics. Further studies are required to elucidate if these changes are a consequence of early loss of skin integrity or a result of mechanical and microclimate insults to the skin surface.


Assuntos
Lesão por Pressão , Humanos , Idoso , Qualidade de Vida , Pele , Queratinócitos , Membrana Celular
6.
J Mech Behav Biomed Mater ; 148: 106168, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37847959

RESUMO

BACKGROUND: Medical adhesives are commonly used for securing wound dressings and medical devices used for diagnostic or therapeutic purposes. Mechanical irritation of skin due to adhesive stripping and repeated application can lead to discomfort and device removal. This study aims to examine the peel strength and skin response to different medical adhesives in a cohort of healthy volunteers. METHOD: Twelve healthy participants were recruited for peel strength testing of three candidate adhesive tapes, and evaluation of the skin response after adhesive removal. A modified ASTM D903 peel strength testing was performed at 180° peeling angle and a rate of 300 mm/min on the forehead, upper back and forearm skin. A longitudinal study was conducted on the forearm and back, with the adhesive samples left in-situ for up to 60 h for analysis of repeat application. The effects of two skin preparation approaches (water and alcohol cleaning) prior to adhesive application were also assessed. Skin biophysical properties were assessed at baseline and at various timepoints following adhesive removal using transepidermal water loss (TEWL), erythema and hydration. RESULTS: Peel strength reduced uniformly with repeat application over prolonged periods for all the adhesive samples tested. Skin preparation with water and alcohol cleansing prior to adhesive application increased peel strength at both the back (1.1% and 2.9%), and forearm (21.3% and 20%) sites. There was statistically significant increase from baseline to post-tape application for TEWL, skin redness and hydration (p < 0.001). However, there were no statistically significant differences between adhesive types (TEWL: p = 0.38, SR: p = 0.53, HY: p = 0.46). TEWL increased the most post-adhesion across all test sites and adhesive samples with repeat application (p < 0.05). Two-way ANOVA tests revealed no statistically significant interactions between the effects of application duration and adhesive on skin redness or TEWL for both the back and forearm sites (p > 0.05), though a significant interaction was indicted for hydration at the back site (p = 0.01). CONCLUSION: This study revealed that site and duration of adhesive application effected peel strength. The corresponding changes in skin properties identified that skin barrier function was disrupted with long-term application of adhesives. The back site was identified to be most reliable for adhesion testing and skin response assessment for future work.


Assuntos
Adesivos , Pele , Humanos , Estudos Longitudinais , Bandagens , Água
7.
Int Wound J ; 20(8): 3164-3176, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37060199

RESUMO

In acute care facilities, the detection of pressure ulcers (PUs) relies on visual and manual examination of the patient's skin, which has been reported to be inconsistent and may lead to misdiagnosis. In skin and wound research, various biophysical parameters have been extensively employed to monitor changes in skin health. Nonetheless, the transition of these measures into care settings as part of a routine clinical assessment has been limited. This study was designed to examine the spatial and temporal changes in skin biophysical parameters over the site of a category I PU, in a cohort of hospitalised patients. Thirty patients, each presenting with a category I PU, were enrolled in the study. Skin integrity was assessed at the PU-compromised site and two adjacent areas (5 and 10 cm away). Data was collected over three sessions to examine both temporal differences and longitudinal changes. Skin integrity was assessed using two biophysical parameters, namely, transepidermal water loss (TEWL) and stratum corneum (SC) hydration. In addition, the influence of intrinsic factors, namely, incontinence and mobility status, on the parameters was evaluated. TEWL values at the sites compromised by PU were statistically significantly greater (P < .001) than corresponding values at the adjacent control sites at 5 and 10 cm, which were consistent with a normative range (<20 g/h/m2 ). By contrast, SC hydration values did not reveal clear distinctions between the three sites, with high inter-patient variation detected at the sites. Nevertheless, individual profiles were consistent across the three sessions, and the PU site was observed to be either abnormally dry or overhydrated in different individuals. No consistent temporal trend in either parameter was evident. However, intrinsic factors were shown to influence the parameters, with females, bedridden and incontinent patients presenting significantly higher TEWL and SC hydration values (P < .05). TEWL was able to identify differences in skin responses at skin sites compromised with a category I PU when compared to healthy adjacent skin sites. Accordingly, this parameter could be included in the clinical assessment for the identification of PU risk. Further studies are required to elucidate the role of hydration and skin barrier function in the development of PUs and their ability to monitor temporal changes in skin integrity.


Assuntos
Lesão por Pressão , Feminino , Humanos , Lesão por Pressão/diagnóstico , Pele , Epiderme , Água , Supuração
8.
J Adv Nurs ; 79(9): 3312-3323, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36919007

RESUMO

AIMS: To explore patient perceptions and understanding of their pressure ulcer risk and how information is communicated between a nurse and patient in the home setting. DESIGN: A pragmatic qualitative research design including community-dwelling patients, who were deemed at risk of developing a pressure ulcer. METHODS: Observation of routine interactions between nurse and patient regarding their pressure ulcer risk and semi-structured interviews with 15 community patients following the nursing interaction. RESULTS: Four key overarching themes emerged from the data analysis that were related to patient perceptions and understanding of pressure ulcer risk. These included Pressure Ulcer Awareness, Importance of Repositioning, Healthy Eating and Risk Interpretation. CONCLUSION: Patient perception and understanding of pressure ulcer risk is different from the scientific, professional view. Patient risk perception was based on heuristics and wider personal factors and social influences. IMPACT: The study provides important new insights into clinical practice in relation to how pressure ulcer advice and information are provided and interpreted in the community setting. REPORTING METHOD: Adhered to the Standards for Reporting Qualitative Research (SRQR) PATIENT OR PUBLIC CONTRIBUTION: A small selection of patients within the NHS Trust in which the research was conducted contributed to the design of the study, in particular some of the interview questions and timing.


Assuntos
Lesão por Pressão , Humanos , Lesão por Pressão/etiologia , Pacientes , Pesquisa Qualitativa
9.
Int Wound J ; 20(7): 2594-2607, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36872612

RESUMO

Pressure Ulcers (PU) are a major burden for affected patients and healthcare providers. Current detection methods involve visual assessments of the skin by healthcare professionals. This has been shown to be subjective and unreliable, with challenges associated with identifying erythema in darker colour skin. Although there exists a number of promising non-invasive biophysical techniques such as ultrasound, capacitance measurements, and thermography, the present study focuses on directly measuring the changes in the inflammatory status of the skin and underlying tissues. Therefore, in this study, we aim to analyse inflammatory cytokines collected through non-invasive sampling techniques to detect early signs of skin damage. Thirty hospitalised patients presenting with Stage I PU were recruited to evaluate the inflammatory response of skin at the site of damage and an adjacent healthy control site. Sebutapes were collected over three sessions to investigate the temporal changes in the inflammatory response. The panel of cytokines investigated included high-abundance cytokines, namely, IL-1α and IL-1RA, and low abundance cytokines; IL-6, IL-8, TNF-α, INF-γ, IL-33, IL-1ß and G-CSF. Spatial and temporal differences between sites were assessed and thresholds were used to determine the sensitivity and specificity of each biomarker. The results suggest significant (P < .05) spatial changes in the inflammatory response, with upregulation of IL-1α, IL-8, and G-CSF as well as down-regulation of IL-1RA over the Stage I PU compared with the adjacent control site. There were no significant temporal differences between the three sessions. Selected cytokines, namely, IL-1α, IL-1RA, IL-8, G-CSF, and the ratio IL-1α/IL-1RA offered clear delineation in the classification of healthy and Stage-I PU skin sites, with receiver operating characteristic curves demonstrating high sensitivity and specificity. There were limited influences of intrinsic and extrinsic factors on the biomarker response. Inflammatory markers provided a high level of discrimination between the sites presenting with Stage I PU and an adjacent healthy skin site, in a cohort of elderly inpatients. Indeed, the ratio of IL-1α to IL-1RA provided the highest sensitivity and specificity, indicative that inflammatory homeostasis is affected at the PU site. There was a marginal influence of intrinsic and extrinsic factors, demonstrating the localised effects of the inflammation. Further studies are required to investigate the potential of inflammatory cytokines incorporated within Point of Care technologies, to support routine clinical use.


Assuntos
Lesão por Pressão , Humanos , Idoso , Lesão por Pressão/diagnóstico , Proteína Antagonista do Receptor de Interleucina 1 , Interleucina-8 , Estudos Longitudinais , Sebo , Citocinas , Estudos de Coortes , Biomarcadores , Pelve , Fator Estimulador de Colônias de Granulócitos
10.
J Tissue Viability ; 32(2): 305-313, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36813598

RESUMO

INTRODUCTION: During the COVID-19 pandemic healthcare workers (HCWs) have used respiratory protective equipment for prolonged periods, which has been associated with detrimental effects on the underlying skin. The present study aims to evaluate changes in the main cells (corneocytes) of the stratum corneum (SC) following prolonged and consecutive use of respirators. METHODS: 17 HCWs who wore respirators daily during routine hospital practice were recruited to a longitudinal cohort study. Corneocytes were collected via tape stripping from a negative control site (area outside the respirator) and from the cheek which was in contact with the device. Corneocytes were sampled on three occasions and analysed for the level of positive-involucrin cornified envelopes (CEs) and the amount of desmoglein-1 (Dsg1), as indirect measurements of immature CEs and corneodesmosomes (CDs), respectively. These were compared to biophysical measurements (Transepidermal water loss, TEWL, and SC hydration) at the same investigation sites. RESULTS: A large degree of inter-subject variability was observed, with maximum coefficients of variation of 43% and 30% for the level of immature CEs and Dsg1, respectively. Although it was observed that there was not an effect of prolonged respirator usage on the properties of corneocytes, the level of CDs was greater at the cheek than the negative control site (p < 0.05). Furthermore, low levels of immature CEs correlated with greater TEWL values after prolonged respirator application (p < 0.01). It was also noted that a smaller proportion of immature CEs and CDs was associated with a reduced incidence of self-reported skin adverse reactions (p < 0.001). CONCLUSIONS: This is the first study that investigated changes in corneocyte properties in the context of prolonged mechanical loading following respirator application. Although differences were not recorded over time, the levels of CDs and immature CEs were consistently higher in the loaded cheek compared to the negative control site and were positively correlated with a greater number of self-reported skin adverse reactions. Further studies are required to evaluate the role of corneocyte characteristics in the evaluation of both healthy and damaged skin sites.


Assuntos
COVID-19 , Pandemias , Humanos , Estudos Longitudinais , COVID-19/prevenção & controle , Ventiladores Mecânicos , Atenção à Saúde
11.
Physiol Behav ; 262: 114112, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36754272

RESUMO

Differences in skin thermal sensitivity have been extensively mapped across areas of the human body, including the torso, limbs, and extremities. Yet, there are parts of the female body, such as the breast and the pelvis for which we have limited thermal sensitivity data. The aim of this study was to map cutaneous warm and cold sensitivity across skin areas of the breast and pelvis that are commonly covered by female underwear. Twelve young females (21.9 ± 3.2 years) reported on a 200 mm visual analogue scale the perceived magnitude of local thermal sensations arising from short-duration (10 s) static application of a cold [5 °C below local skin temperature (Tsk)] or warm (5 °C above local Tsk) thermal probe (25 cm2) in seventeen locations over the breast and pelvis regions. The data revealed that thermal sensitivity to the warm probe, but not the cold probe, varied by up to 25% across the breast [mean difference between lowest and highest sensitivity location was 51 mm (95% CI:14, 89; p < 0.001)] and up to 23% across the pelvis [mean difference between lowest and highest sensitivity location: 46 mm (95% CI:9, 84; p = 0.001)]. The regional differences in baseline Tsk did not account for variance in warm thermal sensitivity. Inter-individual variability in thermal sensitivity ranged between 24 and 101% depending on skin location. We conclude that the skin across the female breast and pelvis presents a heterogenous distribution of warm, but not cold, thermal sensitivity. These findings may inform the design of more comfortable clothing that are mapped to the thermal needs of the female body.


Assuntos
Temperatura Alta , Pele , Humanos , Feminino , Temperatura Cutânea , Sensação Térmica , Temperatura Baixa , Pelve
12.
Skin Res Technol ; 29(2): e13292, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36823505

RESUMO

BACKGROUND: Skin is the largest organ in the body, representing an important interface to monitor health and disease. However, there is significant variation in skin properties for different ages, genders and body regions due to the differences in the structure and morphology of the skin tissues. This study aimed to evaluate the use of non-invasive tools to discriminate a range of mechanical and functional skin parameters from different skin sites. MATERIALS AND METHODS: A cohort of 15 healthy volunteers was recruited following appropriate informed consent. Four well-established CE-marked non-invasive techniques were used to measure four anatomical regions: palm, forearm, sole and lower lumbar L3, using a repeated measures design. Skin parameters included trans-epidermal water loss (TEWL), pH (acidity), erythema, stratum corneum hydration and stiffness and elasticity using Myoton Pro (skin and muscle probe). Differences between body locations for each parameter and the intra-rater reliability between days were evaluated by the same operator. RESULTS: The results indicate that parameters differed significantly between skin sites. For the Myoton skin probe, the sole recorded the highest stiffness value of 1006 N/m (SD ± 179), while the lower lumbar recorded the least value of 484 N/m (SD ± 160). The muscle indenter Myoton probe revealed the palm's highest value of 754 N/m (± 108), and the lower lumbar recorded the least value of 208 N/m (SD ± 44). TEWL values were lowest on the forearm, averaging 11 g/m2/h, and highest on the palm, averaging 41 g/m2/h. Similar skin hydration levels were recorded in three of the four sites, with the main difference being observed in the sole averaging 13 arbitrary units. Erythema values were characterised by a high degree of inter-subject variation, and no significant differences between sites or sides were observed. The Myoton Pro Skin showed excellent reliability (intra-class correlation coefficients > 0.70) for all sites with exception of one site right lower back; the Myoton pro muscle probes showed good to poor reliability (0.90-017), the corneometer showed excellent reliability (>0.75) among all the sites tested, and the TEWL showed Good to poor reliability (0.74-0.4) among sites. CONCLUSION: The study revealed that using non-invasive methods, the biophysical properties of skin can be mapped, and significant differences in the mechanical and functional properties of skin were observed. These parameters were reliably recorded between days, providing a basis for their use in assessing and monitoring changes in the skin during health and disease.


Assuntos
Fenômenos Fisiológicos da Pele , Pele , Humanos , Feminino , Masculino , Reprodutibilidade dos Testes , Pele/metabolismo , Epiderme , Eritema , Água/metabolismo , Perda Insensível de Água/fisiologia
13.
Spinal Cord ; 61(2): 111-118, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35978113

RESUMO

STUDY DESIGN: Cohort observational study. OBJECTIVES: To examine the movement profiles of individuals with spinal cord injury (SCI) during their inpatient rehabilitative phase using continuous pressure monitoring (CPM), evaluating the trends in those with skin damage. SETTING: SCI specialist rehabilitation centre in the United Kingdom. METHODS: Individuals with SCI (n = 12) were assessed using CPM in the bed and chair over a 24-72 h. Pressure data was used as a surrogate for movement using both nursing interpretation and an intelligent algorithm. Clinical features were obtained including participants age, injury level, ASIA score, co-morbidities and prescribed support surfaces. Trends between movement profiles (frequency and intervals), SCI demographics and observed skin damage were assessed using cross-tabulation and histograms. RESULTS: The data revealed significant correlations (p < 0.05) between the nursing observation and algorithm for predicting movement, although the algorithm was more sensitive. Individuals with high level injuries (C1-T6) were observed to have a lower frequency of movement and larger intervals between movements when compared to low level injuries (T7-L5) during both lying and sitting periods. The individuals observed to have skin damage were predominantly those who had both a low frequency of movement and extended gaps between movements. CONCLUSIONS: Movements for pressure relief in both the bed and chair environments were dependent on the level of injury in individuals with SCI during their inpatient rehabilitation. Distinct movement patterns corresponded with those who acquired skin damage, revealing the potential clinical applications for technologies to monitor PU risk and inform personalised care.


Assuntos
Lesão por Pressão , Traumatismos da Medula Espinal , Humanos , Lesão por Pressão/etiologia , Pacientes Internados , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/reabilitação , Estudos de Coortes
15.
PLoS One ; 17(11): e0277570, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36367887

RESUMO

N95/FFP3 respirators have been critical to protect healthcare workers and their patients from the transmission of COVID-19. However, these respirators are characterised by a limited range of size and geometry, which are often associated with fitting issues in particular sub-groups of gender and ethnicities. This study describes a novel methodology which combines magnetic resonance imaging (MRI) of a cohort of individuals (n = 8), with and without a respirator in-situ, and 3D registration algorithm which predicted the goodness of fit of the respirator. Sensitivity analysis was used to optimise a deformation value for the respirator-face interactions and corroborate with the soft tissue displacements estimated from the MRI images. An association between predicted respirator fitting and facial anthropometrics was then assessed for the cohort.


Assuntos
COVID-19 , Dispositivos de Proteção Respiratória , Humanos , COVID-19/prevenção & controle , Respiradores N95 , Ventiladores Mecânicos , Pessoal de Saúde
16.
Med Devices (Auckl) ; 15: 241-252, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35928220

RESUMO

Purpose: Respiratory protective equipment is widely used in healthcare settings to protect clinicians whilst treating patients with COVID-19. However, their generic designs do not accommodate the variability in face shape across genders and ethnicities. Accordingly, they are regularly overtightened to compensate for a poor fit. The present study aims at investigating the biomechanical and thermal loads during respirator application and the associated changes in local skin physiology at the skin-device interface. Materials and Methods: Sixteen healthy volunteers were recruited and reflected a range of gender, ethnicities and facial anthropometrics. Four single-use respirators were evaluated representing different geometries, size and material interfaces. Participants were asked to wear each respirator in a random order while a series of measurements were recorded, including interface pressure, temperature and relative humidity. Measures of transepidermal water loss and skin hydration were assessed pre- and post-respirator application, and after 20 minutes of recovery. Statistical analysis assessed differences between respirator designs and associations between demographics, interface conditions and parameters of skin health. Results: Results showed a statistically significant negative correlation (p < 0.05) between the alar width and interface pressures at the nasal bridge, for three of the respirator designs. The nasal bridge site also corresponded to the highest pressures for all respirator designs. Temperature and humidity significantly increased (p < 0.05) during each respirator application. Significant increases in transepidermal water loss values (p < 0.05) were observed after the application of the respirators in females, which were most apparent at the nasal bridge. Conclusion: The results revealed that specific facial features affected the distribution of interface pressures and depending on the respirator design and material, changes in skin barrier function were evident. The development of respirator designs that accommodate a diverse range of face shapes and protect the end users from skin damage are required to support the long-term use of these devices.

17.
Int J Nurs Stud ; 135: 104326, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35932711

RESUMO

BACKGROUND: Pressure ulcers are a complex healthcare issue. Hospital-acquired pressure ulcers are used as proxy measurements for the quality and safety of nursing care. Medical device-related pressure ulcers are mostly facility acquired, but their reporting has only recently been widely adopted. Consequently, we do not yet know what factors impact their reporting by registered nurses. OBJECTIVES: To identify and systematically report determinants of the practice of medical device-related pressure ulcers reporting using the Tailored Implementation for Chronic Diseases checklist. DESIGN: Descriptive, explorative design using semi-structured interviews to explore barriers and facilitators to reporting medical device-related pressure ulcers. SETTING: We undertook online, telephone, and face-to-face interviews with participants from 11 different countries. PARTICIPANTS: We interviewed 17 participants who represented acute care (Adult, Paediatrics), academia, and industry. Eleven participants were healthcare professionals with more than 10 years' experience in wound care. METHODS: The interview recordings were transcribed and coded by the lead researcher. Data were analysed thematically using the codebook approach, and themes were developed inductively and deductively. RESULTS: Participants identified determinants of practice which clustered around four domains of the Tailored Implementation for Chronic Diseases checklist i) individual health professional factors, ii) professional interactions, iii) incentives and resources, and iv) capacity for organisational change. Knowledge, attitudes, workload, time, staffing, and perception of consequences, including financial, were identified as the main barriers to reporting. Factors supporting the practice were education, openness, and teamwork. Device procurement could take on characteristics of a barrier or facilitator depending on the organisation. CONCLUSIONS: Reporting medical device-related pressure ulcers has been adopted in healthcare institutions worldwide. Understanding what drives the reporting practice enables improvements in incident reporting, which consequently can lead to improvements in the quality of nursing care and patient safety.


Assuntos
Lesão por Pressão , Adulto , Criança , Pessoal de Saúde , Humanos , Segurança do Paciente , Lesão por Pressão/etiologia , Pesquisa Qualitativa , Gestão de Riscos
18.
J Tissue Viability ; 31(1): 119-129, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34949521

RESUMO

Pressure ulcers (PUs) occur in a range of care settings, resulting in reduced quality of life for the individual. There has been a growing awareness that medical devices can cause PUs, although reporting has been limited. There is a need to evaluate PU reporting practice and identify whether standards exist for medical device-related pressure ulcers (MDRPUs). AIM: To synthesize academic and grey literature relevant to reporting of PUs and MDRPUs in healthcare settings. METHODS: A systematic search of multiple scientific and grey literature databases was undertaken. Key search terms and Boolean operators were used to identify relevant literature. All sources of evidence discussing reporting practices were included in a synthesis. Primary topics are discussed in the corresponding analysis. RESULTS: Thirty-one evidence sources met the inclusion criteria, including 16 journal articles and 15 policy and guidance documents. The results revealed a variation in reporting practices. MDRPUs were often not identified as a separate category in local and national systems. Policies for related patient safety reporting varied across all organisational levels, with more serious categories of PUs reported more consistently. Reporting to medical device regulatory bodies was not mandatory. CONCLUSION: This narrative review identified inconsistencies in local and national reporting of PUs and MDRPUs, prohibiting meaningful comparisons and improvements in patient safety. Lack of specific medical device data and low levels of voluntary reporting to regulatory bodies is likely to result in an under-reporting, with little evidence of specific devices which may be a patient safety concern.


Assuntos
Lesão por Pressão , Humanos , Políticas , Lesão por Pressão/etiologia , Lesão por Pressão/prevenção & controle , Qualidade de Vida
19.
J Sep Sci ; 45(2): 542-550, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34796639

RESUMO

Liquid chromatography-mass spectrometry methods were required to afford the rapid separation and detection of purines and small organic acids. These compounds are found in sweat and sebum and are potential biomarkers for the early detection of pressures sores. Two ultra-high-performance supercritical fluid chromatography-mass spectrometry assays have been successfully developed for both classes of compounds. Separation for purines was achieved using a gradient of supercritical carbon dioxide and methanol with a 1-aminoanthracene sub 2 µm particle size column followed by positive ion electrospray ionization. Separation for organic acids was achieved using a gradient of supercritical carbon dioxide and methanol (50 mM ammonium acetate 2% water) with a Diol sub 2 µm particle size column followed by negative ion electrospray ionization. Calibration curves were created in the absence of internal standards and R2 values > 0.96 were achieved using single ion monitoring methods for the protonated purines and the deprotonated acids. The two new assays afford rapid analytical methods for the separation and detection of potential biomarkers in human sweat leading to the early detection and prevention of pressure sores.


Assuntos
Cromatografia com Fluido Supercrítico , Biomarcadores , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia com Fluido Supercrítico/métodos , Humanos , Espectrometria de Massas , Suor
20.
Skin Res Technol ; 28(1): 187-199, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34708455

RESUMO

BACKGROUND: Skin sensitivity (SS) is a commonly occurring response to a range of stimuli, including environmental conditions (e.g., sun exposure), chemical irritants (e.g., soaps and cosmetics), and mechanical forces (e.g., while shaving). From both industry and academia, many efforts have been taken to quantify the characteristics of SS in a standardised manner, but the study is hindered by the lack of an objective definition. METHODS: A review of the scientific literature regarding different parameters attributed to the loss of skin integrity and linked with exhibition of SS was conducted. Articles included were screened for mechanical stimulation of the skin, with objective quantification of tissue responses using biophysical or imaging techniques. Additionally, studies where cohorts of SS and non-SS individuals were reported have been critiqued. RESULTS: The findings identified that the structure and function of the stratum corneum and its effective barrier properties are closely associated with SS. Thus, an array of skin tissue responses has been selected for characterization of SS due to mechanical stimuli, including: transepidermal water loss, hydration, redness, temperature, and sebum index. Additionally, certain imaging tools allow quantification of the superficial skin layers, providing structural characteristics underlying SS. CONCLUSION: This review proposes a multimodal approach for identification of SS, providing a means to characterise skin tissue responses objectively. Optical coherence tomography (OCT) has been suggested as a suitable tool for dermatological research with clinical applications. Such an approach would enhance the knowledge underlying the multifactorial nature of SS and aid the development of personalised solutions in medical and consumer devices.


Assuntos
Fenômenos Fisiológicos da Pele , Pele , Epiderme , Eritema , Humanos , Sebo
SELEÇÃO DE REFERÊNCIAS